DigiPower-PDU-MIB DEFINITIONS ::= BEGIN

IMPORTS
	TRAP-TYPE
		FROM RFC-1215
	DisplayString
		FROM RFC1213-MIB
	OBJECT-TYPE
		FROM RFC-1212
	enterprises
		FROM RFC1155-SMI;


digipower OBJECT IDENTIFIER 	::= { enterprises 17420 }

products OBJECT IDENTIFIER 	::= { digipower 1 }

devTable OBJECT IDENTIFIER	::= { products 2 }

envthreshold OBJECT IDENTIFIER	::= { products 4 }

-- DEV basic information --

devID OBJECT-TYPE
	SYNTAX INTEGER (1..16)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"The ID number of dev."
	::= { devTable 1 }


devIP OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..128))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current IP address, netmask, default gateway, and DNS server."
	::= { devTable 2 }


devMAC OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate current MAC address."
	::= { devTable 3 }


devVersion OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate current firmware version."
	::= { devTable 4 }


devInfo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the count of attached PDUs and their id."
	::= { devTable 5 }


devValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the PDU values (currents) from PDU1 to PDU16"
	::= { devTable 6 }

devTemperature OBJECT-TYPE
	SYNTAX INTEGER (-50..100)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the PDU temperature in Celsius degree"
	::= { devTable 7 }

devHumidity OBJECT-TYPE
	SYNTAX INTEGER (0..100)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the PDU humidity in percentage (%)"
	::= { devTable 8 }

pduTable OBJECT IDENTIFIER	::= { devTable 9 }


-- PDU entries --
-- PDU01 --

pdu01Entry OBJECT IDENTIFIER	::= { pduTable 1 }


pdu01Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-01 detect."
	::= { pdu01Entry 11 }


pdu01SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu01Entry 12 }


pdu01OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu01Entry 13 }


pdu01OutletConfigs OBJECT IDENTIFIER	::= { pdu01Entry 14 }


pdu01Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu01OutletConfigs 1 }


pdu01Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu01OutletConfigs 2 }


pdu01Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu01OutletConfigs 3 }


pdu01Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu01OutletConfigs 4 }


pdu01Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu01OutletConfigs 5 }


pdu01Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu01OutletConfigs 6 }


pdu01Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu01OutletConfigs 7 }


pdu01Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu01OutletConfigs 8 }


pdu01Outlet9Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet9"
	::= { pdu01OutletConfigs 9 }


pdu01Outlet10Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet10"
	::= { pdu01OutletConfigs 10 }
	
	
pdu01Outlet11Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet11"
	::= { pdu01OutletConfigs 11 }


pdu01Outlet12Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet12"
	::= { pdu01OutletConfigs 12 }


pdu01Outlet13Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet13"
	::= { pdu01OutletConfigs 13 }


pdu01Outlet14Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet14"
	::= { pdu01OutletConfigs 14 }


pdu01Outlet15Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet15"
	::= { pdu01OutletConfigs 15 }


pdu01Outlet16Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet16"
	::= { pdu01OutletConfigs 16 }


pdu01Outlet17Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet17"
	::= { pdu01OutletConfigs 17 }


pdu01Outlet18Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet18"
	::= { pdu01OutletConfigs 18 }


pdu01Outlet19Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet19"
	::= { pdu01OutletConfigs 19 }


pdu01Outlet20Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet20"
	::= { pdu01OutletConfigs 20 }


pdu01Outlet21Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet21"
	::= { pdu01OutletConfigs 21 }


pdu01Outlet22Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet22"
	::= { pdu01OutletConfigs 22 }


pdu01Outlet23Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet23"
	::= { pdu01OutletConfigs 23 }


pdu01Outlet24Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet24"
	::= { pdu01OutletConfigs 24 }
	
	
pdu01Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu01Entry 15 }


pdu01Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu01Entry 16 }


pdu01Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu01Entry 17 }


pdu01ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu01Entry 18 }


pdu01ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu01Entry 19 }


pdu01Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu01Entry 20 }
	
pdu01DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..128))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu01Entry 21 }	

pdu01DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..128))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu01Entry 22 }	

-- PDU02 --

pdu02Entry OBJECT IDENTIFIER	::= { pduTable 2 }

pdu02Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-02 detect."
	::= { pdu02Entry 11 }


pdu02SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu02Entry 12 }


pdu02OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu02Entry 13 }


pdu02OutletConfigs OBJECT IDENTIFIER	::= { pdu02Entry 14 }


pdu02Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu02OutletConfigs 1 }


pdu02Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu02OutletConfigs 2 }


pdu02Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu02OutletConfigs 3 }


pdu02Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu02OutletConfigs 4 }


pdu02Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu02OutletConfigs 5 }


pdu02Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu02OutletConfigs 6 }


pdu02Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu02OutletConfigs 7 }


pdu02Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu02OutletConfigs 8 }


pdu02Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu02Entry 15 }


pdu02Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu02Entry 16 }


pdu02Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu02Entry 17 }


pdu02ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu02Entry 18 }


pdu02ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu02Entry 19 }


pdu02Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu02Entry 20 }

pdu02DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..128))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu02Entry 21 }	

pdu02DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu02Entry 22 }	
	
-- PDU03 --

pdu03Entry OBJECT IDENTIFIER	::= { pduTable 3 }


pdu03Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-03 detect."
	::= { pdu03Entry 11 }


pdu03SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu03Entry 12 }


pdu03OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu03Entry 13 }


pdu03OutletConfigs OBJECT IDENTIFIER	::= { pdu03Entry 14 }


pdu03Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu03OutletConfigs 1 }


pdu03Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu03OutletConfigs 2 }


pdu03Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu03OutletConfigs 3 }


pdu03Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu03OutletConfigs 4 }


pdu03Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu03OutletConfigs 5 }


pdu03Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu03OutletConfigs 6 }


pdu03Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu03OutletConfigs 7 }


pdu03Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu03OutletConfigs 8 }


pdu03Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu03Entry 15 }


pdu03Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu03Entry 16 }


pdu03Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu03Entry 17 }


pdu03ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu03Entry 18 }


pdu03ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu03Entry 19 }


pdu03Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu03Entry 20 }

pdu03DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu03Entry 21 }	

pdu03DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu03Entry 22 }	
	
-- PDU04 --

pdu04Entry OBJECT IDENTIFIER	::= { pduTable 4 }


pdu04Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-04 detect."
	::= { pdu04Entry 11 }


pdu04SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu04Entry 12 }


pdu04OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu04Entry 13 }


pdu04OutletConfigs OBJECT IDENTIFIER	::= { pdu04Entry 14 }

pdu04Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu04OutletConfigs 1 }


pdu04Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu04OutletConfigs 2 }


pdu04Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu04OutletConfigs 3 }


pdu04Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu04OutletConfigs 4 }


pdu04Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu04OutletConfigs 5 }


pdu04Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu04OutletConfigs 6 }


pdu04Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu04OutletConfigs 7 }


pdu04Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu04OutletConfigs 8 }


pdu04Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu04Entry 15 }


pdu04Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu04Entry 16 }


pdu04Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu04Entry 17 }


pdu04ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu04Entry 18 }


pdu04ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu04Entry 19 }


pdu04Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu04Entry 20 }

pdu04DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu04Entry 21 }	

pdu04DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu04Entry 22 }	
	
-- PDU05 --

pdu05Entry OBJECT IDENTIFIER	::= { pduTable 5 }

pdu05Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-05 detect."
	::= { pdu05Entry 11 }


pdu05SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu05Entry 12 }


pdu05OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu05Entry 13 }


pdu05OutletConfigs OBJECT IDENTIFIER	::= { pdu05Entry 14 }


pdu05Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu05OutletConfigs 1 }


pdu05Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu05OutletConfigs 2 }


pdu05Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu05OutletConfigs 3 }


pdu05Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu05OutletConfigs 4 }


pdu05Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu05OutletConfigs 5 }


pdu05Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu05OutletConfigs 6 }


pdu05Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu05OutletConfigs 7 }


pdu05Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu05OutletConfigs 8 }


pdu05Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu05Entry 15 }


pdu05Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu05Entry 16 }


pdu05Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu05Entry 17 }


pdu05ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu05Entry 18 }


pdu05ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu05Entry 19 }


pdu05Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu05Entry 20 }

pdu05DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu05Entry 21 }	

pdu05DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu05Entry 22 }	
	
-- PDU06 --

pdu06Entry OBJECT IDENTIFIER	::= { pduTable 6 }


pdu06Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-06 detect."
	::= { pdu06Entry 11 }


pdu06SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu06Entry 12 }


pdu06OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		-1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu06Entry 13 }


pdu06OutletConfigs OBJECT IDENTIFIER	::= { pdu06Entry 14 }


pdu06Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu06OutletConfigs 1 }


pdu06Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu06OutletConfigs 2 }


pdu06Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu06OutletConfigs 3 }


pdu06Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu06OutletConfigs 4 }


pdu06Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu06OutletConfigs 5 }


pdu06Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu06OutletConfigs 6 }


pdu06Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu06OutletConfigs 7 }


pdu06Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu06OutletConfigs 8 }


pdu06Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu06Entry 15 }


pdu06Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu06Entry 16 }


pdu06Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu06Entry 17 }


pdu06ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu06Entry 18 }


pdu06ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu06Entry 19 }


pdu06Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu06Entry 20 }

pdu06DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu06Entry 21 }	

pdu06DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu06Entry 22 }	
	
-- PDU07 --

pdu07Entry OBJECT IDENTIFIER	::= { pduTable 7 }


pdu07Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-07 detect."
	::= { pdu07Entry 11 }


pdu07SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu07Entry 12 }


pdu07OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu07Entry 13 }


pdu07OutletConfigs OBJECT IDENTIFIER	::= { pdu07Entry 14 }


pdu07Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu07OutletConfigs 1 }


pdu07Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu07OutletConfigs 2 }


pdu07Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu07OutletConfigs 3 }


pdu07Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu07OutletConfigs 4 }


pdu07Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu07OutletConfigs 5 }


pdu07Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu07OutletConfigs 6 }


pdu07Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu07OutletConfigs 7 }


pdu07Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu07OutletConfigs 8 }


pdu07Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu07Entry 15 }


pdu07Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu07Entry 16 }


pdu07Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu07Entry 17 }


pdu07ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu07Entry 18 }


pdu07ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu07Entry 19 }


pdu07Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu07Entry 20 }

pdu07DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu07Entry 21 }	

pdu07DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu07Entry 22 }	
	
-- PDU08 --

pdu08Entry OBJECT IDENTIFIER	::= { pduTable 8 }


pdu08Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-08 detect."
	::= { pdu08Entry 11 }


pdu08SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu08Entry 12 }


pdu08OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu08Entry 13 }


pdu08OutletConfigs OBJECT IDENTIFIER	::= { pdu08Entry 14 }


pdu08Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu08OutletConfigs 1 }


pdu08Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu08OutletConfigs 2 }


pdu08Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu08OutletConfigs 3 }


pdu08Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu08OutletConfigs 4 }


pdu08Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu08OutletConfigs 5 }


pdu08Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu08OutletConfigs 6 }


pdu08Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu08OutletConfigs 7 }


pdu08Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu08OutletConfigs 8 }


pdu08Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu08Entry 15 }


pdu08Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu08Entry 16 }


pdu08Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu08Entry 17 }


pdu08ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu08Entry 18 }


pdu08ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu08Entry 19 }


pdu08Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu08Entry 20 }

pdu08DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu08Entry 21 }	

pdu08DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu08Entry 22 }	
	
-- PDU09 --

pdu09Entry OBJECT IDENTIFIER	::= { pduTable 9 }


pdu09Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-09 detect."
	::= { pdu09Entry 11 }


pdu09SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu09Entry 12 }


pdu09OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu09Entry 13 }


pdu09OutletConfigs OBJECT IDENTIFIER	::= { pdu09Entry 14 }


pdu09Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu09OutletConfigs 1 }


pdu09Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu09OutletConfigs 2 }


pdu09Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu09OutletConfigs 3 }


pdu09Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu09OutletConfigs 4 }


pdu09Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu09OutletConfigs 5 }


pdu09Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu09OutletConfigs 6 }


pdu09Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu09OutletConfigs 7 }


pdu09Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu09OutletConfigs 8 }


pdu09Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu09Entry 15 }


pdu09Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu09Entry 16 }


pdu09Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu09Entry 17 }


pdu09ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu09Entry 18 }


pdu09ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu09Entry 19 }


pdu09Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu09Entry 20 }

pdu09DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu09Entry 21 }	

pdu09DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu09Entry 22 }	
	
-- PDU10 --

pdu10Entry OBJECT IDENTIFIER	::= { pduTable 10 }


pdu10Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-10 detect."
	::= { pdu10Entry 11 }


pdu10SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu10Entry 12 }


pdu10OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu10Entry 13 }


pdu10OutletConfigs OBJECT IDENTIFIER	::= { pdu10Entry 14 }


pdu10Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu10OutletConfigs 1 }


pdu10Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu10OutletConfigs 2 }


pdu10Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu10OutletConfigs 3 }


pdu10Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu10OutletConfigs 4 }


pdu10Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu10OutletConfigs 5 }


pdu10Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu10OutletConfigs 6 }


pdu10Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu10OutletConfigs 7 }


pdu10Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu10OutletConfigs 8 }


pdu10Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu10Entry 15 }


pdu10Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu10Entry 16 }


pdu10Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu10Entry 17 }


pdu10ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu10Entry 18 }


pdu10ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu10Entry 19 }


pdu10Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu10Entry 20 }

pdu10DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu10Entry 21 }	

pdu10DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu10Entry 22 }	
	
-- PDU11 --

pdu11Entry OBJECT IDENTIFIER	::= { pduTable 11 }


pdu11Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-11 detect."
	::= { pdu11Entry 11 }


pdu11SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu11Entry 12 }


pdu11OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu11Entry 13 }


pdu11OutletConfigs OBJECT IDENTIFIER	::= { pdu11Entry 14 }


pdu11Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu11OutletConfigs 1 }


pdu11Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu11OutletConfigs 2 }


pdu11Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu11OutletConfigs 3 }


pdu11Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu11OutletConfigs 4 }


pdu11Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu11OutletConfigs 5 }


pdu11Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu11OutletConfigs 6 }


pdu11Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu11OutletConfigs 7 }


pdu11Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu11OutletConfigs 8 }


pdu11Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu11Entry 15 }


pdu11Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu11Entry 16 }


pdu11Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu11Entry 17 }


pdu11ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu11Entry 18 }


pdu11ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu11Entry 19 }


pdu11Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu11Entry 20 }

pdu11DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu11Entry 21 }	

pdu11DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu11Entry 22 }	
	
-- PDU12 --

pdu12Entry OBJECT IDENTIFIER	::= { pduTable 12 }


pdu12Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-12 detect."
	::= { pdu12Entry 11 }


pdu12SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu12Entry 12 }


pdu12OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu12Entry 13 }


pdu12OutletConfigs OBJECT IDENTIFIER	::= { pdu12Entry 14 }


pdu12Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu12OutletConfigs 1 }


pdu12Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu12OutletConfigs 2 }


pdu12Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu12OutletConfigs 3 }


pdu12Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu12OutletConfigs 4 }


pdu12Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu12OutletConfigs 5 }


pdu12Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu12OutletConfigs 6 }


pdu12Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu12OutletConfigs 7 }


pdu12Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu12OutletConfigs 8 }


pdu12Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu12Entry 15 }


pdu12Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu12Entry 16 }


pdu12Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu12Entry 17 }


pdu12ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu12Entry 18 }


pdu12ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu12Entry 19 }


pdu12Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu12Entry 20 }

pdu12DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu12Entry 21 }	

pdu12DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu12Entry 22 }	
	
-- PDU13 --

pdu13Entry OBJECT IDENTIFIER	::= { pduTable 13 }


pdu13Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-13 detect."
	::= { pdu13Entry 11 }


pdu13SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu13Entry 12 }


pdu13OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu13Entry 13 }


pdu13OutletConfigs OBJECT IDENTIFIER	::= { pdu13Entry 14 }


pdu13Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu13OutletConfigs 1 }


pdu13Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu13OutletConfigs 2 }


pdu13Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu13OutletConfigs 3 }


pdu13Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu13OutletConfigs 4 }


pdu13Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu13OutletConfigs 5 }


pdu13Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu13OutletConfigs 6 }


pdu13Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu13OutletConfigs 7 }


pdu13Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu13OutletConfigs 8 }


pdu13Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu13Entry 15 }


pdu13Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu13Entry 16 }


pdu13Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu13Entry 17 }


pdu13ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu13Entry 18 }


pdu13ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu13Entry 19 }


pdu13Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu13Entry 20 }

pdu13DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu13Entry 21 }	

pdu13DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu13Entry 22 }	
	
-- PDU14 --

pdu14Entry OBJECT IDENTIFIER	::= { pduTable 14 }


pdu14Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-14 detect."
	::= { pdu14Entry 11 }


pdu14SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu14Entry 12 }


pdu14OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu14Entry 13 }


pdu14OutletConfigs OBJECT IDENTIFIER	::= { pdu14Entry 14 }


pdu14Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu14OutletConfigs 1 }


pdu14Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu14OutletConfigs 2 }


pdu14Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu14OutletConfigs 3 }


pdu14Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu14OutletConfigs 4 }


pdu14Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu14OutletConfigs 5 }


pdu14Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu14OutletConfigs 6 }


pdu14Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu14OutletConfigs 7 }


pdu14Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu14OutletConfigs 8 }


pdu14Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu14Entry 15 }


pdu14Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu14Entry 16 }


pdu14Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu14Entry 17 }


pdu14ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu14Entry 18 }


pdu14ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu14Entry 19 }


pdu14Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu14Entry 20 }

pdu14DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu14Entry 21 }	

pdu14DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu14Entry 22 }	
	
-- PDU15 --

pdu15Entry OBJECT IDENTIFIER	::= { pduTable 15 }


pdu15Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-15 detect."
	::= { pdu15Entry 11 }


pdu15SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu15Entry 12 }


pdu15OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu15Entry 13 }


pdu15OutletConfigs OBJECT IDENTIFIER	::= { pdu15Entry 14 }


pdu15Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu15OutletConfigs 1 }


pdu15Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu15OutletConfigs 2 }


pdu15Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu15OutletConfigs 3 }


pdu15Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu15OutletConfigs 4 }


pdu15Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu15OutletConfigs 5 }


pdu15Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu15OutletConfigs 6 }


pdu15Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu15OutletConfigs 7 }


pdu15Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu15OutletConfigs 8 }


pdu15Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu15Entry 15 }


pdu15Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu15Entry 16 }


pdu15Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu15Entry 17 }


pdu15ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu15Entry 18 }


pdu15ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu15Entry 19 }


pdu15Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu15Entry 20 }

pdu15DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu15Entry 21 }	

pdu15DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu15Entry 22 }	
	
-- PDU16 --

pdu16Entry OBJECT IDENTIFIER	::= { pduTable 16 }


pdu16Value OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the current of PDU-16 detect."
	::= { pdu16Entry 11 }


pdu16SubValues OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet values (currents) from Outlet1 to Outlet8"
	::= { pdu16Entry 12 }


pdu16OutletStatus OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the outlet statuses (On or Off) from Outlet1 to Outlet8
		 1: Outlet ON
		 0: Outlet OFF
		 -1: Outlet is not available
		 -2: Outlet powr lost or Breaker triggered"
	::= { pdu16Entry 13 }


pdu16OutletConfigs OBJECT IDENTIFIER	::= { pdu16Entry 14 }


pdu16Outlet1Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet1"
	::= { pdu16OutletConfigs 1 }


pdu16Outlet2Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet2"
	::= { pdu16OutletConfigs 2 }


pdu16Outlet3Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet3"
	::= { pdu16OutletConfigs 3 }


pdu16Outlet4Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet4"
	::= { pdu16OutletConfigs 4 }


pdu16Outlet5Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet5"
	::= { pdu16OutletConfigs 5 }


pdu16Outlet6Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet6"
	::= { pdu16OutletConfigs 6 }


pdu16Outlet7Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet7"
	::= { pdu16OutletConfigs 7 }


pdu16Outlet8Config OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..64))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate the configuration of Outlet8"
	::= { pdu16OutletConfigs 8 }


pdu16Threshold1 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 1 (warning current)."
	::= { pdu16Entry 15 }


pdu16Threshold2 OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate current threshold 2 (critical current)."
	::= { pdu16Entry 16 }


pdu16Voltage OBJECT-TYPE
	SYNTAX INTEGER (0..999)
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate voltage of PDU."
	::= { pdu16Entry 17 }


pdu16ModelName OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model name."
	::= { pdu16Entry 18 }


pdu16ModelNo OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU model number."
	::= { pdu16Entry 19 }


pdu16Identify OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU identify."
	::= { pdu16Entry 20 }

pdu16DelayOn OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet On delay time. Unit is second "
	::= { pdu16Entry 21 }	

pdu16DelayOff OBJECT-TYPE
	SYNTAX      DisplayString (SIZE (0..32))
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate PDU Outlet Off delay time. Unit is second "
	::= { pdu16Entry 22 }	
	

-- ENV Threshold information --

tempLower OBJECT-TYPE
	SYNTAX INTEGER (1..16)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate temperature lower threshold"
	::= { envthreshold 42 }
	
tempUpper OBJECT-TYPE
	SYNTAX INTEGER (1..16)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate temperature upper threshold"
	::= { envthreshold 43 }
	
humidityLower OBJECT-TYPE
	SYNTAX INTEGER (1..16)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate humidity lower threshold"
	::= { envthreshold 44 }
	
humidityLower OBJECT-TYPE
	SYNTAX INTEGER (1..16)
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"Indicate humidity upper threshold"
	::= { envthreshold 45 }
	
--dev traps ----------------------------------------------------------------

--pdu01TrapEntry TRAP-TYPE
--	ENTERPRISE digipower
--	ACCESS not-accessible
--	STATUS mandatory
--	DESCRIPTION
--		"An entry containing trap information of PDU-01."
--	::= 1

--pdu01CommunicationLost TRAP-TYPE
--	SYNTAX pdu01CommunicationLost
--	DESCRIPTION
--		"PDU-01 communication lost."
--	:: = { pdu01TrapEntry 19 }


devOutOfThreshold1 TRAP-TYPE
	ENTERPRISE digipower
	DESCRIPTION 
		"WARNING: DEV current out of threshold 1."
 ::= 105


devOutOfThreshold2 TRAP-TYPE
	ENTERPRISE digipower
	DESCRIPTION 
		"CRITICAL: DEV current out of threshold 2."
 ::= 106


--devCommunicationLost TRAP-TYPE
--	ENTERPRISE digipower
--	DESCRIPTION 
--		"CRITICAL: DEV Communication lost."
-- ::= 107

devBackToNormal TRAP-TYPE
	ENTERPRISE digipower
	DESCRIPTION
		"NORMAL: DEV back to normal states"
 ::= 108

END