--  DLINKSW-DDM-MIB.mib : Digital Diagnostics Monitoring (DDM) MIB
--
--  Copyright (c) 2013 D-Link Corporation, all rights reserved.
--
--  *****************************************************************
DLINKSW-DDM-MIB DEFINITIONS ::= BEGIN
    IMPORTS
        DisplayString,TruthValue,RowStatus
            FROM SNMPv2-TC
        MODULE-IDENTITY,OBJECT-TYPE,Integer32
            FROM SNMPv2-SMI
        MODULE-COMPLIANCE,OBJECT-GROUP
		    FROM SNMPv2-CONF
        SnmpAdminString					
            FROM SNMP-FRAMEWORK-MIB
        ifIndex, InterfaceIndex
            FROM IF-MIB    
        dlinkIndustrialCommon		
            FROM DLINK-ID-REC-MIB;
   
    dlinkSwDdmMIB	MODULE-IDENTITY
   		LAST-UPDATED "201302040000Z"
   		ORGANIZATION "D-Link Corp."
        CONTACT-INFO
            "        D-Link Corporation

             Postal: No. 289, Sinhu 3rd Rd., Neihu District,
                     Taipei City 114, Taiwan, R.O.C
             Tel:     +886-2-66000123
             E-mail: tsd@dlink.com.tw
            "
        DESCRIPTION
            "This MIB module defines objects for DDM."
            
        REVISION "201302040000Z"
        DESCRIPTION
		    "The structure of DDM for the proprietary enterprise."
		    
        REVISION "201309050000Z"
        DESCRIPTION
            "Modified the object dDdmAlarmTrap and dDdmWarningTrap to
            support to send traps when transceiver monitoring recovers from an
            abnormal warning/alarm situation to normal status."
        ::={ dlinkIndustrialCommon 72 } 


    DlinkThresholdState ::= TEXTUAL-CONVENTION
        STATUS  current
        DESCRIPTION
            "Represents the state of a current monitoring value.
             Valid values are:
            
            normal(0): the current value is within normal range.

            higherAlarm(1):  the current value is higher than the high alarm threshold.

            higherWarning(2): the current value is higher than the high warning threshold.       

            lowerWarning(3):  the current value is lower than the low warning threshold.   

            lowerAlarm(4): the current value is lower than the low alarm threshold.       
            "
        SYNTAX  INTEGER {
            normal(0),
            higherAlarm(1),
            higherWarning(2),
            lowerWarning(3),
            lowerAlarm(4)                      
        }
                
	dDdmMIBNotifications 		OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 0 }
	dDdmMIBObjects 			    OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 1 }
	dDdmMIBConformance		    OBJECT IDENTIFIER ::= { dlinkSwDdmMIB 2 }

-- -------------------------------------------------------------------------- 
    dDdmCtrl			OBJECT IDENTIFIER ::= { dDdmMIBObjects 1 }
    
    dDdmNotifyEnable OBJECT-TYPE
        SYNTAX          BITS {
            alarm(0),
            warning(1)
        }
        MAX-ACCESS  read-write
        STATUS      current
        DESCRIPTION
            "This object indicates whether a specified notification is enabled or not.
            If a bit corresponding to a notification is set to 1, then 
            the specified notification can be generated.

            alarm(0)   - sending an alarm level notification. 
            warning(1) - sending an warning level notification.              
            "
        ::= { dDdmCtrl 1 }
        

-- -------------------------------------------------------------------------- 		
     dDdmIfCtrl			OBJECT IDENTIFIER ::= { dDdmMIBObjects 2 }
            
     dDdmIfCfgTable	OBJECT-TYPE
		SYNTAX          SEQUENCE OF DDdmIfCfgEntry
		MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION
            "This table contains a list of interface-specific DDM configuration."
        ::= {dDdmIfCtrl 1}
      
    dDdmIfCfgEntry	OBJECT-TYPE
		SYNTAX	        DDdmIfCfgEntry
		MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION
            "An entry manages DDM state and action on an interface."
        INDEX  {  ifIndex }
      ::= {dDdmIfCfgTable 1}
      
    DDdmIfCfgEntry ::=
        SEQUENCE {
            dDdmIfCfgEnabled     TruthValue,
            dDdmShutdownLevel    INTEGER     
        }  
             
    dDdmIfCfgEnabled OBJECT-TYPE
		SYNTAX          TruthValue 	 	 
        MAX-ACCESS      read-write
        STATUS          current
        DESCRIPTION
            "This object indicates the status of optical transceiver-monitoring
            function for a SFP port.
            When a SFP with transceiver-monitoring capability is plugged in a
            port but the transceiver-monitoring function of the port is
            disabled, system will not detect the SFP's abnormal status but user
            still can check the current status via dDdmIfInfoTable."
        ::= {dDdmIfCfgEntry 1} 
    
    dDdmShutdownLevel OBJECT-TYPE
		SYNTAX  INTEGER {					
            none(1),
            alarm(2),
            warning(3)
        }
        MAX-ACCESS      read-write
        STATUS           current
        DESCRIPTION
             "This object indicates the abnormal level which causes a port
             enter into errDisabled state.
             A value of 'none' indicates the shutdown action is disabled.
             "
        ::= {dDdmIfCfgEntry 2}    
              
-- --------------------------------------------------------------------------
    dDdmThresholdMgmt			OBJECT IDENTIFIER ::= { dDdmMIBObjects 3 }
    
    dDdmThresholdCfgTable	OBJECT-TYPE
		SYNTAX          SEQUENCE OF DDdmThresholdCfgEntry
		MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION
            "This table contains a list of interface-specific threshold configuration for
            DDM."
        ::= {dDdmThresholdMgmt 1}
        
    dDdmThresholdCfgEntry OBJECT-TYPE
		SYNTAX          DDdmThresholdCfgEntry
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION
            "An entry in this table conists of one threshold configuration on an interface.
            An entry is created/removed when a configuration is added/deleted.
            "
        INDEX  { 
            ifIndex,
            dDdmThresholdComponent,
            dDmThresholdAbnormalLevel
        }
        ::= { dDdmThresholdCfgTable 1 }

    DDdmThresholdCfgEntry	::=
        SEQUENCE {
            dDdmThresholdComponent          INTEGER,
            dDmThresholdAbnormalLevel       INTEGER,
  		    dDdmThresholdCfgValue           Integer32,
  		    dDdmThresholdCfgRowStatus       RowStatus
  	    }
        		             
    dDdmThresholdComponent	OBJECT-TYPE
		SYNTAX	INTEGER {
            temperature(1),
            voltage(2),
            biasCurrent(3),
            txPowerMw(4),
            txPowerDbm(5),            
            rxPowerMw(6),
            rxPowerDbm(7)
        }  
        MAX-ACCESS      not-accessible
        STATUS          current
        DESCRIPTION
            "This object indicates the monitoring type.
            Note:
            Either txPowerMw(4) or txPowerDbm(5) can be configured on an interface.
            Either rxPowerMw(6) or rxPowerDbm(7) can be configured on an interface.
            In the above two cases, the existed entry will be deleted when the 
            other new entry is created.
            "
        ::= {dDdmThresholdCfgEntry 1}  
            
    dDmThresholdAbnormalLevel	OBJECT-TYPE
		SYNTAX	INTEGER {
            highAlarm(1),
            highWarning(2),
            lowWarning(3),
            lowAlarm(4)       
        }  
        MAX-ACCESS  not-accessible
        STATUS      current
        DESCRIPTION
            "This object indicates the threshold type."
        ::= { dDdmThresholdCfgEntry 2 }      
        
   dDdmThresholdCfgValue	OBJECT-TYPE
		SYNTAX          Integer32
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION
            "This object indicates the configured threshold. The value is
            interpreted within the context of dDdmThresholdComponent and
            dDmThresholdAbnormalLevel in the same row. The unit and valid range
            are as follows:
            Threshold Type     Unit                           Valid Range
            =============      =====================          =================
            Temperature        milli-degrees Celsius          -128,000 ~ 127,996 
            voltage            centi-Volt                     0 ~ 655
            biasCurrent        milli-amperes                  0 ~ 131 
            txPowerMw          tenths of a microwatt            0 ~ 65,535
            txPowerDbm         ten-thousandths of DBM         -400,000 ~ 81,647
            rxPowerMw          tenths of a microwatt            0 ~ 65,535
            rxPowerDbm         ten-thousandths of DBM         -400,000 ~ 81,647            
            "
        ::= { dDdmThresholdCfgEntry 3 }  
        
    dDdmThresholdCfgRowStatus 	OBJECT-TYPE
		SYNTAX          RowStatus
        MAX-ACCESS      read-create
        STATUS          current
        DESCRIPTION
            "The status of this conceptual row."
        ::= { dDdmThresholdCfgEntry 4 }  
                         
-- -------------------------------------------------------------------------- 
    dDdmInfo  OBJECT IDENTIFIER ::= {  dDdmMIBObjects 4 }

    dDdmIfInfoTable	OBJECT-TYPE
		SYNTAX	        SEQUENCE OF DDdmIfInfoEntry
		MAX-ACCESS      not-accessible
		STATUS          current
        DESCRIPTION
            "This table contains a list of information about current operating
            parameters of interfaces. Only the applicable interfaces (i.e.SFP
            module with DDM capability is plugged-in. ) will appear in this table.
            Note: 
            1. The threshold may be administratively configured or factory
               preset value defined by vendors. dDdmThresholdCfgTable provides
               the administrative threshold configuration.
            2. It doesn't necessarily means the DDM is enabled on the interface
               when an entry appears in this table. dDdmIfCfgTable provides such
               information."
        ::= {dDdmInfo 1}
        
    dDdmIfInfoEntry OBJECT-TYPE
		SYNTAX	        DDdmIfInfoEntry
		MAX-ACCESS      not-accessible
		STATUS	        current
		DESCRIPTION
			"An entry appears in this table contains current operating parameters
			for transceiver monitoring of a port."       
		INDEX  { ifIndex  }
		::= { dDdmIfInfoTable 1}
		
    DDdmIfInfoEntry ::=
		SEQUENCE {		    
		   dDdmIfInfoCurrentTemperature         Integer32,
		   dDdmIfInfoTemperatureState           DlinkThresholdState,
		   dDdmIfInfoHighAlarmTemperature       Integer32,
		   dDdmIfInfoHighWarnTemperature        Integer32,           
		   dDdmIfInfoLowWarnTemperature         Integer32,	
		   dDdmIfInfoLowAlarmTemperature        Integer32,	   
		   dDdmIfInfoCurrentVoltage             Integer32,
		   dDdmIfInfoVoltageState               DlinkThresholdState,
		   dDdmIfInfoHighAlarmVoltage           Integer32,
		   dDdmIfInfoHighWarnVoltage            Integer32,           
		   dDdmIfInfoLowWarnVoltage             Integer32,
		   dDdmIfInfoLowAlarmVoltage            Integer32,		   
		   dDdmIfInfoCurrentBiasCurrent         Integer32,
		   dDdmIfInfoBiasCurrentState           DlinkThresholdState,
		   dDdmIfInfoHighAlarmBiasCurrent       Integer32,
		   dDdmIfInfoHighWarnBiasCurrent        Integer32,
		   dDdmIfInfoLowWarnBiasCurrent         Integer32,   
           dDdmIfInfoLowAlarmBiasCurrent        Integer32,		  
		   dDdmIfInfoCurrentTxPower             Integer32,
		   dDdmIfInfoTxPowerState               DlinkThresholdState,
		   dDdmIfInfoHighAlarmTxPower           Integer32,
		   dDdmIfInfoHighWarnTxPower            Integer32,
		   dDdmIfInfoLowWarnTxPower             Integer32,
           dDdmIfInfoLowAlarmTxPower            Integer32,           
		   dDdmIfInfoCurrentRxPower             Integer32,
		   dDdmIfInfoRxPowerState               DlinkThresholdState,		   
		   dDdmIfInfoHighAlarmRxPower           Integer32,
		   dDdmIfInfoHighWarnRxPower            Integer32,           
		   dDdmIfInfoLowWarnRxPower             Integer32,
		   dDdmIfInfoLowAlarmRxPower            Integer32
        }
 
    dDdmIfInfoCurrentTemperature OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "milli-degrees Celsius"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the current temperature in unit of 
            'milli-degrees Celsius' on the interface."
        ::= { dDdmIfInfoEntry 1 }
        
    dDdmIfInfoTemperatureState OBJECT-TYPE
        SYNTAX          DlinkThresholdState   
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the state of current temperature."
        ::= { dDdmIfInfoEntry 2 }
    
    dDdmIfInfoHighAlarmTemperature OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "milli-degrees Celsius"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the high alarm threshold, when the operating
            temperature rises above this value, it indicates an alarm status.           
            The value is in unit of 'milli-degrees Celsius'."
        ::= { dDdmIfInfoEntry 3 }     
      
      
    dDdmIfInfoHighWarnTemperature OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "milli-degrees Celsius"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the high warning threshold, when the operating
            temperature rises above this value, it indicates a warning status.
            The value is in unit of 'milli-degrees Celsius'."
        ::= { dDdmIfInfoEntry 4 }       
    
    dDdmIfInfoLowWarnTemperature OBJECT-TYPE       
        SYNTAX          Integer32
        UNITS           "milli-degrees Celsius"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the low warning threshold, when the operating
            temperature falls below this value, it indicates a warning status.
            The value is in unit of 'milli-degrees Celsius'."
        ::= { dDdmIfInfoEntry 5 }     
      
    dDdmIfInfoLowAlarmTemperature OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "milli-degrees Celsius"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the low alarm threshold, when the operating
            temperature falls below this value, it indicates an alarm status.
            The value is in unit of 'milli-degrees Celsius'."
        ::= { dDdmIfInfoEntry 6 }            
   
    dDdmIfInfoCurrentVoltage OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "centi-Volt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the current voltage in unit of 
            'centi-Volt' on the interface."
        ::= { dDdmIfInfoEntry 7 }
        
    dDdmIfInfoVoltageState OBJECT-TYPE
        SYNTAX          DlinkThresholdState             
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the state of current voltage."
        ::= { dDdmIfInfoEntry 8 }
    
    dDdmIfInfoHighAlarmVoltage OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "centi-Volt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the high alarm threshold, when the operating
            voltage rises above this value, it indicates an alarm status.
            The value is in unit of 'centi-Volt'."
        ::= { dDdmIfInfoEntry 9 }     
      
    dDdmIfInfoHighWarnVoltage OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "centi-Volt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the high warning threshold, when the operating
            voltage rises above this value, it indicates a warning status.
            The value is in unit of 'centi-Volt'."
        ::= { dDdmIfInfoEntry 10 }       
    
    dDdmIfInfoLowWarnVoltage OBJECT-TYPE       
        SYNTAX          Integer32
        UNITS           "centi-Volt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the low warning threshold, when the operating
            voltage falls below this value, it indicates a warning status.
            The value is in unit of 'centi-Volt'."
        ::= { dDdmIfInfoEntry 11 }     
      
    dDdmIfInfoLowAlarmVoltage OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "centi-Volt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the low alarm threshold, when the operating
            voltage falls below this value, it indicates an alarm status.
            The value is in unit of 'centi-Volt'."
        ::= { dDdmIfInfoEntry 12 }             
   
   dDdmIfInfoCurrentBiasCurrent OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "milli-amperes"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the current bias current in unit of 
            'milli-amperes' on the interface."
        ::= { dDdmIfInfoEntry 13 }
        
    dDdmIfInfoBiasCurrentState OBJECT-TYPE
        SYNTAX          DlinkThresholdState
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the state of current BiasCurrent."
        ::= { dDdmIfInfoEntry 14 }
    
    dDdmIfInfoHighAlarmBiasCurrent OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "milli-amperes"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the high alarm threshold, when the operating
            bias current rises above this value, it indicates an alarm status.
            The value is in unit of 'milli-amperes'."
        ::= { dDdmIfInfoEntry 15 }     
      
    dDdmIfInfoHighWarnBiasCurrent OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "milli-amperes"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the high warning threshold, when the operating
            bias current rises above this value, it indicates a warning status.
            The value is in unit of 'milli-amperes'."
        ::= { dDdmIfInfoEntry 16 }       
    
    dDdmIfInfoLowWarnBiasCurrent OBJECT-TYPE       
        SYNTAX          Integer32
        UNITS           "milli-amperes"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the low warning threshold, when the operating
            bias current falls below this value, it indicates a warning status.
            The value is in unit of 'milli-amperes'."
        ::= { dDdmIfInfoEntry 17 }     
      
    dDdmIfInfoLowAlarmBiasCurrent OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "milli-amperes"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the low alarm threshold, when the operating
            bias current falls below this value, it indicates an alarm status.
            The value is in unit of 'milli-amperes'."
        ::= { dDdmIfInfoEntry 18 }            

    dDdmIfInfoCurrentTxPower OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "tenths of a microwatt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the current output power in unit of 
            'tenths of a microwatt' on the interface."
        ::= { dDdmIfInfoEntry 19 }
        
    dDdmIfInfoTxPowerState OBJECT-TYPE
        SYNTAX          DlinkThresholdState
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the state of current output power."
        ::= { dDdmIfInfoEntry 20 }
    
    dDdmIfInfoHighAlarmTxPower OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "tenths of a microwatt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the high alarm threshold, when the operating
            output power rises above this value, it indicates an alarm status.
            The value is in unit of 'tenths of a microwatt'."
        ::= { dDdmIfInfoEntry 21 }     
      
    dDdmIfInfoHighWarnTxPower OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "tenths of a microwatt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the high warning threshold, when the operating
            output power rises above this value, it indicates a warning status.
            The value is in unit of 'tenths of a microwatt'."
        ::= { dDdmIfInfoEntry 22 }       
    
    dDdmIfInfoLowWarnTxPower OBJECT-TYPE       
        SYNTAX          Integer32
        UNITS           "tenths of a microwatt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the low warning threshold, when the operating
            output power falls below this value, it indicates a warning status.
            The value is in unit of 'tenths of a microwatt'."
        ::= { dDdmIfInfoEntry 23 }     
      
    dDdmIfInfoLowAlarmTxPower OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "tenths of a microwatt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the low alarm threshold, when the operating
            output power falls below this value, it indicates an alarm status.
            The value is in unit of 'tenths of a microwatt'."
        ::= { dDdmIfInfoEntry 24 }  
        
    dDdmIfInfoCurrentRxPower OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "tenths of a microwatt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the current input power in unit of 
            'tenths of a microwatt' on the interface."
        ::= { dDdmIfInfoEntry 25 }
        
    dDdmIfInfoRxPowerState OBJECT-TYPE
        SYNTAX          DlinkThresholdState
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the state of current input power."
        ::= { dDdmIfInfoEntry 26 }
    
    dDdmIfInfoHighAlarmRxPower OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "tenths of a microwatt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the high alarm threshold, when the operating
            input power rises above this value, it indicates an alarm status.
            The value is in unit of 'tenths of a microwatt'."
        ::= { dDdmIfInfoEntry 27 }     
      
    dDdmIfInfoHighWarnRxPower OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "tenths of a microwatt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the high warning threshold, when the operating
            input power rises above this value, it indicates a warning status.
            The value is in unit of 'tenths of a microwatt'."
        ::= { dDdmIfInfoEntry 28 }       
    
    dDdmIfInfoLowWarnRxPower OBJECT-TYPE       
        SYNTAX          Integer32
        UNITS           "tenths of a microwatt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the low warning threshold, when the operating
            input power falls below this value, it indicates a warning status.
            The value is in unit of 'tenths of a microwatt'."
        ::= { dDdmIfInfoEntry 29 }     
      
    dDdmIfInfoLowAlarmRxPower OBJECT-TYPE
        SYNTAX          Integer32
        UNITS           "tenths of a microwatt"
        MAX-ACCESS      read-only
        STATUS          current
        DESCRIPTION
            "This object indicates the low alarm threshold, when the operating
            input power falls below this value, it indicates an alarm status.
            The value is in unit of 'tenths of a microwatt'."
        ::= { dDdmIfInfoEntry 30 }  
        
-- --------------------------------------------------------------------------
   dDdmNotifyInfo  OBJECT IDENTIFIER ::= {  dDdmMIBObjects 5 }

   dDdmNotifyInfoIfIndex OBJECT-TYPE
		SYNTAX 	        InterfaceIndex
		MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION
              "This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate 
              the ifIndex on which the monitoring value rises above or falls below
              the corresponding threshold."
              ::= { dDdmNotifyInfo 1 }
  
    dDdmNotifyInfoComponent OBJECT-TYPE
		SYNTAX 	INTEGER{
			temperature(1),
            voltage(2),
            biasCurrent(3),
            txPowerMw(4),                        
            rxPowerMw(5)           
	    }
		MAX-ACCESS      accessible-for-notify
        STATUS          current
        DESCRIPTION
              "This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate  
              the abnormal component."
        ::= { dDdmNotifyInfo 2 }
         
    dDdmNotifyInfoAbnormalLevel OBJECT-TYPE
		SYNTAX 	INTEGER{
			high(1),
			low(2)
		}
		MAX-ACCESS  accessible-for-notify
        STATUS  current
        DESCRIPTION
            "This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate  
            the abnormal level."
        ::= { dDdmNotifyInfo 3 }
        
    dDdmNotifyInfoThresholdExceedOrRecover OBJECT-TYPE
		SYNTAX 	INTEGER{
					exceed(1),
					recover(2)
			}
		MAX-ACCESS  accessible-for-notify
    STATUS  current
    DESCRIPTION
        "This object is used by dDdmAlarmTrap and dDdmWarningTrap to indicate the
        GBIC is exceeding its threshold or recover to
        normal status."
        ::= {dDdmNotifyInfo 4}
             
 
-- --------------------------------------------------------------------------

    dDdmAlarmTrap NOTIFICATION-TYPE
        OBJECTS  {
            dDdmNotifyInfoIfIndex,
            dDdmNotifyInfoComponent,
            dDdmNotifyInfoAbnormalLevel,
            dDdmNotifyInfoThresholdExceedOrRecover    					
        }        
        STATUS          current
        DESCRIPTION
            "The trap is sent when dDdmNotifyEnable is 'true' and an abnormal 
            alarm situation occurs or recovers from an abnormal alarm situation
            to normal status."
      ::= { dDdmMIBNotifications 1 }
      
    dDdmWarningTrap NOTIFICATION-TYPE
        OBJECTS         {
    	    dDdmNotifyInfoIfIndex,
    	    dDdmNotifyInfoComponent, 
    	    dDdmNotifyInfoAbnormalLevel,
            dDdmNotifyInfoThresholdExceedOrRecover   						  					
       }        
       STATUS              current
       DESCRIPTION
            "The trap is sent when dDdmNotifyEnable is 'true' and an abnormal 
            warning situation occurs or recovers from an abnormal warning
            situation to normal status."
      ::= { dDdmMIBNotifications 2 }

--  ***************************************************************************	
--  Conformance
--  ***************************************************************************			   		
	dDdmCompliances OBJECT IDENTIFIER ::= { dDdmMIBConformance 1 }
		
	dDdmCompliance MODULE-COMPLIANCE
		STATUS current
		DESCRIPTION 
			"The compliance statement for entities which implement the 
			DLINKSW-DDM-MIB."
		MODULE -- this module
		MANDATORY-GROUPS { 
		    dDdmInfoGroup,
		    dDdmCfgGroup,
		    dDdmNotifyGroup        		   
		}						
		::= { dDdmCompliances 1 }
		
	dDdmGroups OBJECT IDENTIFIER ::= { dDdmMIBConformance 2 }
	
	dDdmInfoGroup OBJECT-GROUP
		OBJECTS { 
             dDdmIfInfoCurrentTemperature, dDdmIfInfoTemperatureState,
             dDdmIfInfoHighAlarmTemperature, dDdmIfInfoHighWarnTemperature,              
             dDdmIfInfoLowWarnTemperature, dDdmIfInfoLowAlarmTemperature,              
             dDdmIfInfoCurrentVoltage, dDdmIfInfoVoltageState,        
             dDdmIfInfoHighAlarmVoltage, dDdmIfInfoHighWarnVoltage,                  
             dDdmIfInfoLowWarnVoltage, dDdmIfInfoLowAlarmVoltage,     
             dDdmIfInfoCurrentBiasCurrent, dDdmIfInfoBiasCurrentState,    
             dDdmIfInfoHighAlarmBiasCurrent, dDdmIfInfoHighWarnBiasCurrent, 
             dDdmIfInfoLowWarnBiasCurrent, dDdmIfInfoLowAlarmBiasCurrent, 
             dDdmIfInfoCurrentTxPower, dDdmIfInfoTxPowerState,
             dDdmIfInfoHighAlarmTxPower, dDdmIfInfoHighWarnTxPower,
             dDdmIfInfoLowWarnTxPower, dDdmIfInfoLowAlarmTxPower,
             dDdmIfInfoCurrentRxPower, dDdmIfInfoRxPowerState,
             dDdmIfInfoHighAlarmRxPower, dDdmIfInfoHighWarnRxPower,
             dDdmIfInfoLowWarnRxPower, dDdmIfInfoLowAlarmRxPower,
             dDdmNotifyInfoIfIndex, dDdmNotifyInfoComponent,
             dDdmNotifyInfoAbnormalLevel,
             dDdmNotifyInfoThresholdExceedOrRecover    						
		}
		STATUS current
		DESCRIPTION 
			"A collection of objects provides DDM operating information."
		::= { dDdmGroups 1 }
        
    dDdmCfgGroup OBJECT-GROUP
		OBJECTS { 
			dDdmNotifyEnable,
			dDdmIfCfgEnabled, dDdmShutdownLevel,
			dDdmThresholdCfgValue,	dDdmThresholdCfgRowStatus 
			
		}
		STATUS current
		DESCRIPTION 
			"A collection of objects provides DDM configuration."
		::= { dDdmGroups 2 }    
	
	dDdmNotifyGroup NOTIFICATION-GROUP
		NOTIFICATIONS { 
			dDdmAlarmTrap,
			dDdmWarningTrap
		}
		STATUS current
		DESCRIPTION 
			"The collection of notifications used for DDM."
		::= { dDdmGroups 3 }      
      
END